Innovation with 35 years of professional intelligence

EAE BUSBAR SYSTEMS

Indoor Low-Voltage Busbar Systems

  •  690 V / 1000V
  • IP55 protection
  • With copper or aluminum conductors
  • With 3; 4; 4.5; 5, 6 internal conductors
  • Housing, made from aluminum or sheet steel, can be used as a standard PE conductor
  • Rated current = 25A – 6300A

power Busbars

E-Line KX - 400A - 6300A (KX-II, KX-III)
  • Tap-off boxes up to 160A – 1000A
  • External Mechanical Impacts (IK Code): Bolt-on Busbar IK10+, Plug-in Busbar IK08
  • There is no need for internal fire barriers, only external fireproofing is required when passing it through a fireproof wall
  • The system has feeder boxes, panel connection elements and transformer connection elements, the connection to the transformer is solved with a custom-made copper flexible connection set, as well as straight
    elements with plug-in possibility and without it
  • Typical conductor configuration L1, L2, L3, N, PE (housing), L1, L2, L3, N, 50% PE + PE (clean earth)
  • The conductors are full-length tin-plated, aluminum or copper conductors
  • With a 120-minute fire resistance (1000°C according to IEC 60331-1 and 60331-21 standards)
E-Line KO-II - 160A - 800A
  • Tap-off boxes up to 32A – 400A
  • External Mechanical Impacts (IK Code): Bolt-on Busbar IK10+, Plug-in Busbar IK09
  • When passing the bus bar through the fireproof wall, we make a special custom-made element with an internal fireproof barrier, the standard bus bar is internally air-insulated, and external fireproofing is required as well
  • The standard straight element has 5 tap off outlets on each side
  • Typical conductor configuration L1, L2, L3, N, PE (housing), L1, L2, L3, N, 50% PE + PE (clean earth)
  • The conductors are full-length tin-plated, aluminum or copper conductors
E-Line KL - 160A - 1250A
  •  Tap-off boxes up to 32A – 400A
  • External Mechanical Impacts (IK Code): Bolt-on Busbar IK10+, Plug-in Busbar IK09
  • Plug-in tap-off outlets at every 50 cm on both sides as standard
  • Typical conductor configuration L1, L2, L3, N, PE (housing), L1, L2, L3, N, 50% PE + PE (clean earth)
  • The conductors are full-length tin-plated, aluminum or copper conductors
E-Line MK – 100A up to 250A
  •  Tap-off boxes up to 16A – 80A
  • Provides transfer and distribution of energy at the current levels between 100A and 250A
    (aluminum or copper conductors)
  • 4, 4.5 or 5 conductors
  • Plug-in tap off outlets at every 60 cm on both sides as standard
E-Line KD Data Rack Busbar – 160A - 1000A
  •  Plug & Play
  • Flexibility in Rack Cabinet Power Feeding
  • Power up the critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System to meet the „configurability” challenge in the Data Centers finding the way to Moves, Adds and Changes (MACs)
  • The Data Rack Busbar also serves for powering and metering of non-standard Cabinet Rows in data centers white space environments
  • Tap-off boxes up to 80A – 125A
  • External Mechanical Impacts (IK Code): IK08
  • Tap-Off boxes can be plugged in at any point along the busbar easily, therefore making it convenient to remove and relocate wherever necessary
  • Vendor neutral components for energy monitoring
  • The choice of aluminum or copper up to 6 conductors enables design and budget flexibility while the mono block joint mechanism provides peace of mind for secure and long-life operations
  • IP23D protection
E-Line KAM (Lighting) - 25A - 32A & KAP (Small Power) - 40A - 63A
  •  Tap-off boxes up to 10A – 32A
  • E-Line KAP Busbar Systems can be used to feed lighting and small power installations in commercial and industrial buildings such as offices, factories, workshops, warehouses and airports
  • Standard 2, 3, 4 or 5 conductors
  • One plug-in output point on one side at every 75 cm as standard
Dabline – 63A - 80A
  • Tap-off boxes up to 13A – 32A
  • Underfloor Busbar Trunking Power Distribution Systems, used in raised floor applications in offices
  • Various housing color options
  • The compact size of the product makes it possible to install the system into restricted areas with a floor height up to 65 mm
  • For plain, easy and fast solutions minimizing the risk under the raised floor without requiring cable tray, cabling, junction box and connector
E-Line FL-FLD – 32A
  • Easy and fast mounting, can be fixed on any structure or surface using brackets
  • Can be used separately for power or UPS sockets requirements when needed
  • Private power and UPS sockets with aesthetic design and different color options can be installed without any hand tools to desired point
  • Single phase circuit (3 conductors); L+N+(PE) (65×28 mm)
  • Mains or UPS Sockets: 16A, 250V (child protected)
  • IP2X Protection Class

Lighting Busbars

E-Line DL / DL-DALI / DL-DIM
  • Utilized in low power circuits that require 25A – 32A – 40A single phase or three phase electricity in buildings and industrial facilities
  • 10A / 16A tap off plugs (with and without cartridge fuse) are designed to supply lighting circuits according to their attributes

 

E-LINE DL: dual-circuit busbar trunking systems are utilized in offices and workplaces on lighting circuits as well as in raised ceiling industrial facilities on lighting circuits. (2+2) … (5+5) and different conductor combinations are available

E-LINE DL DALI: it is utilized in buildings and industrial plants with DALI controlled lighting circuits for both power supply and control line. In three phase applications (4+4) or (5+4) CE (earth) conductor options or in single phase applications (2+4) or (3+4) CE (earth) conductor options are available

E-LINE DL DIM: it is utilized in buildings and industrial facilities, on lighting circuits and for sectional dimming of fixtures used with corridor ballast function as well as for supplying power. Three phase application is available for 5+4 conductor option

E-Line SL / SL-ACK / SL-DALI+ACK

The E-Line SL Single phase Busbar trunking system has been manufactured as a basic system and supersedes the E-Line KAM lighting busbar range. It is used in factories, offices and parking garages for feeding single phase lighting. Single phase or three phase usage and 2, 3, 4, 5 conductors options in single phase are available

E-LINE SL-ACK: it is used in factories, offices and car parks for feeding single-phase DALI-controlled lighting. Single-phase usage and 5 conductors options in single phase are available

E-Line KY-S
  • Tap-off boxes up to 10A – 32A
  • It is used to provide electrical current to single circuit lighting and emergency lighting circuits, for
    machines that require low power at factories, offices, and parking garages
  • For a single housing, it includes 2, 3, 4, 5, and 6 conductors with the opportunity to be utilized in a single or
    three-phase application
  • One plug-in output point at standard 100 cm intervals

Outdoor Low-Voltage Busbar Systems

  • 1000V
  • IP68 protection
  • With copper or aluminum conductors
  • With 3; 4; 4.5; 5, 6 full internal conductors
E-Line CR (Cast Resin) - 630A - 6300A
  • Solid DURACOMP cast resin insulation
  • With a 180-minute fire resistance (1000°C according to IEC 60331-1 and 60331-21 standards)
  • Up to 6 full internal conductors
  • Busbar trunking systems (E-Line CR Busbar: Cast Resin Busbar) provides the transfer and distribution of electrical current between 630A and 6300A
  • Explosion proof and compatible with E-line KX busbar modules
  • IP 68 protection class
  • The „DURACOMP” synthesized material which has a high temperature and mechanical working strength composed of specially selected pure silicon minerals and epoxy resin, thereby protecting the E-Line CR busbar from external impacts
  • Using “Cast Resin Busbars” in outdoor environments, gallery transitions, chemical plants, harbor applications, tunnels instead of cables that are applied as mandatory offers many advantages. The heat forming in conductors due to additives with high heat transfer capability used in the busbar system is easily transferred to the medium via the body
E-Line CCR – 600A - 6300A
  • With 180-minute fire resistance (1000°C according to IEC 60331-1 and 60331-21 standards)
  • Solid DURACOMP cast resin internal insulation with aluminum housing
  • Housing can be used as a standard PE conductor
  • Provides transfer and distribution of energy at the current levels between 600A – 6300A
  • Aluminum housing covers the “DURACOMP” composite material that is manufactured from specially selected pure silicium minerals and epoxy resin and has superior temperature, and mechanical operation features and insulates the E-Line CCR Busbar from external elements
  • Thanks to the superior heat transfer additives used in the Busbar system, the heat generated in conductors is easily transmitted into the environment through the housing
E-Line MV – 950A - 5000A - Medium-Voltage Busbar System
  • Outdoor IP 68 level protection
  • Manufactured within a single housing, copper or aluminum conductor is embedded in DURACOMP insulation
  • High short circuit resistance due to compact structure
  • E-Line MV busbar is produced by combining the DURACOMP insulated conductor within an extruded aluminum housing
  • Heat forming on the additives used in the system with high heat transfer is easily dissipated to the environment by means of housing